Analisa Stabilitas Dinding Penahan Tanah Ruas Jalan Kambelu-Nasiri Kecamatan Huamual Kabupaten Seram Bagian Barat

Authors

  • Aprilia Agnes Talaud Jurusan Teknik Sipil, Politeknik Negeri Ambon
  • Anthoneta Maitimu Jurusan Teknik Sipil, Polieknik Negeri Ambon
  • Sjafrudin Latar Jurusan Teknik Sipil, Polieknik Negeri Ambon

DOI:

https://doi.org/10.61722/jinu.v2i1.4070

Keywords:

Stability of retaining walls, bolsters, gerers, bearing capacity

Abstract

The Kambelu Hamlet-Nasiri Hamlet road section is a road section that connects several hamlets in Huamual Balik District, West Seram Regency. Functional length 1200m ( STA 00+000 – 01+200) and paving width 4m. This road section often occurs landslides on the slopes around the road section, especially at STA 00+300, STA 00+350, STA 00+400. There was one point that experienced a severe landslide at STA 00+400. This study is to analyze the appropriate soil retaining wall on the Kmbelu - Nasiri road, Huamual Balik District, West Seram Regency.The methods (SNI) for moisture content testing (SNI 1965:2008), content weight testing (SNI 03-3637-1994), specific gravity testing (SNI 1964:2008), filter analysis testing (SNI ASTM C136:2012), atterberg limit testing (SNI 1967:2008) and soil compaction testing (SNI 1742:2008). The methods used are the Rankine method and the Terzhagi method. The distribution of active and passive lateral soil pressure is active soil pressure (Pa) = 75.751 active soil moment = 151.50 kN/ passive soil pressure = 21.042 kN/ passive soil moment = 7.007 kN/ The design of the soil retaining wall is a cantilever type with dimensions, H = 6 m, B = 4 m. The planned type and dimensions have been adjusted to the dimensions of the landslide on the Kambelu - Nasiri STA 00 + 400 road section. And the results of stability to shear force = 2.621 ≥ 2.0 (safe), stability to rolling force ≥ 2.0 (safe) and stability to ground carrying capacity Qult = 868.333  > 108.488 are said to be safe because the maximum Q value is no more than the Qult value.

References

Dermawan, A., Syaiful, S., Alimuddin, A., & Fachruddin, F. (2022). Analisis Stabilitas Dinding Penahan Tanah (Studi Kasus: Desa Mekarjaya, Kecamatan Ciomas, Kabupaten Bogor). Rona Teknik Pertanian, 15(2), 67-81.

Hatulesila, K., Latar, S., & Johannes, S. (2024). ANALISIS DINDING PENAHAN TANAH PADA RUAS JALAN TRANS SERAM DESA LUMOLI KABUPATEN SERAM BAGIAN BARAT. Journal Agregate, 3(1), 100-109.

Soumahu, V., Lewakabessy, G., & Latar, S. (2023). PERENCANAAN DINDING PENAHAN TANAH UNTUK MENANGGULANGI KELONGSORAN PADA RUAS JALAN HUTUMURI KECAMATAN LEITIMUR SELATAN. Journal Agregate, 2(2), 271-284.

Das, Braja M. (2007). Principles of Foundation Engineering 6th Edition.PasificGrove: PWS Publishing.

Hardiyatmo, H.C., 2015. Perancangan Perkerasan Jalan Dan Penyelidikan Tanah. Cetakan Ke-2, Gadjah Mada University Press, Yogyakarta.

Hardiyatmo, Hary Christady. 2011. Analisis dan Perancangan Fondasi I Edisi 2.Yogyakarta: Gajah Mada University Press.

Hardiyatmo, Hary Christady. 2020. Analisis dan Perancangan Fondasi I Edisi 4.Yogyakarta: Gajah Mada University Press. SNI 03-3637-1994. Standar Pengujian Berat Isi Tanah. Badan Standarisasi Nasional.

Maruapey, S., Betaubun, R. J., & Jakob, J. C. (2024). Evaluasi Saluran Drainase Jalan Wolter Monginsidi Passo Kecamatan Baguala Kota Ambon. KOLONI, 3(1), 116-122.

SNI 1742:2008-Cara A. Standar Pengujian Kepadatan Tanah. Badan Standarisasi Nasional.

SNI 1964:2008. Standar Pengujian Berat Isi. Badan Standarisasi Nasional.

SNI 1965:2008. Standar Pengujian Kadar Air. Badan Standarisasi Nasional.

SNI 1967:2008-Cara A. Standar Pengujian Batas Cair. Badan Standarisasi Nasional.

SNI 2813:2008. Standar Pengujian Geser Langsung. Badan Standarisasi Nasional.

SNI ASTM C136:2012. Standar Pengujian Analisa Saringan agregat halus dan kasar (Sieving Analysis Test ). Badan Standarisasi Nasional.