Analisa Kinerja Pompa Terhadap Arus Pada Motor Induksi 3 Fasa Di PT. Pusri Palembang
DOI:
https://doi.org/10.61722/jssr.v4i6.13349Keywords:
Pump Performance, Three-Phase Induction Motor, Electric Current, Pump Efficiency, Induction Motor Power, RefrigerationAbstract
The performance of a pump refers to its ability to transfer fluid from one location to another, measured by parameters such as flow rate, pressure, power consumption, and the operational efficiency of the pump. A three-phase induction motor is an electric motor that operates using a three-phase power supply. In this motor, the magnetic field generated by the three-phase current is used to rotate the rotor and produce mechanical power. Pump efficiency is the ratio between the power generated by the pump to move the fluid and the power consumed by the pump. This efficiency indicates how effectively the pump can convert electrical or mechanical energy into useful fluid energy. The power of the induction motor is the amount of mechanical energy produced by the induction motor, derived from electrical energy. This power can be calculated using formulas involving the motor's current, voltage, and power factor. The power of the induction motor can also be used to drive mechanical devices such as pumps and compressors. The amount of motor power determines the motor capacity required for a specific application. Refrigeration is the process of reducing the temperature in a space or object using a cooling system to transfer heat from a cooler location to a hotter one, using a refrigerant as the heat transfer medium. This thesis discusses the analysis of pump performance relative to current in a three-phase induction motor using a quantitative research method. The results of the calculations show that at a flow rate of 2810 RPM, the highest slip is 6.33%, while at 2976 RPM, the lowest slip is 1.46%. The change in output power with increasing flow rate starts from 2810 RPM (P1 = 44.627 W) to 2976 RPM (P5 = 51.211 W). Meanwhile, the motor speed adjustment using flow rate versus torque ranges from 2810 RPM (Torque1 = 151.88 Nm) to 2976 RPM (Torque5 = 165.448 Nm).
References
Reza pratama, “Analisis Sistem Proteksi Motor Induksi 3 Fasa 380 V Pada Belt Conveyor Di PT Bukit Asam TBK Unit Dermaga Kertapati”, Palembang, 2021.
Ahmad Dansah, “Analisis Sistem Proteksi Pada Motor Induksi Tiga Fasa Sebagai Penggerak Pompa Greasing Pada belt Wagon 301 di PT Bukit Asam TBK”, Palembang, 2021
Krisno Deto Nugroho, “Analisa Gangguan Pada Motor Induksi 3 Fassa Sebagai Penggerak Pompa Untuk Menghisap Air PDAM Di Gedung Palembang Indah Mall”, Palembang, 2019
Jamaaludin, Izza Anshory, Indah Sulistiyowati dan Ahmad Ahfas, “Pengantar Teknik Tenaga Listrik”, UMSIDA PRESS, 2022
IEC. 60034-1, “ spesifikasi umum untuk motor listrik dan secara khusus memberikan pedoman mengenai kinerja, konstruksi, dan karakteristik motor listrik berputar”, 2002
Marapaung “ Teknik Tenaga Listrik”.
Ricky widianto “ Analisa Daya Motor Induksi Tiga Fasa Sebagai Penggerak Belt Conveyor 4852-V Di PT. Pupuk Sriwidjaja Palembang”. Universitas Sriwijaya, 2019
Downloads
Published
Issue
Section
License
Copyright (c) 2026 JOURNAL SAINS STUDENT RESEARCH

This work is licensed under a Creative Commons Attribution-ShareAlike 4.0 International License.











